1. ZBN-YJV22 flame retardant Class B fire-resistant armored cable product introduction:
ZBN-YJV22 cable: copper conductor flame-retardant class B fire-resistant cross-linked polyethylene insulated PVC inner sheath steel tape armored PVC outer sheath force cable. XLPE insulated (YJ), PVC sheathed (V), steel tape armored (22), Class B flame retardant (ZB) power cable, fire resistant (N).
2. ZBN-YJV22 flame retardant fire resistant armored cable product parameters:
Product model: ZBN-YJV22
Rated voltage: 0.6/1KV
Product color: black
Number of cores: single core, two core, three core, four core, five core, 3 1 core, 3 2 core, 4 1 core
Cross section: single core (10mm2 -- 630 mm2), two core (4mm2 -- 400 mm2), three core (2.5 mm2 -- 400 mm2),
Four cores, five cores (1.5 mm2 -400 mm2), 31 cores, 32 cores (2.5 mm2 -400 mm2)
Length: can be cut according to customer requirements, support customized
Scope of application: suitable for power frequency rated voltage 0.6/1kv and distribution network or industrial installation in the laying.
2. ZBN-YJV22 flame retardant fire resistant armored cable use:
1, armored cable mechanical protection layer can be added to any structure of the cable, in order to increase the mechanical strength of the cable, improve the ability to prevent erosion, is vulnerable to mechanical damage and vulnerable to erosion of the area and the design of the wire and cable.
2. It can be laid in any way, which is more suitable for direct buried laying in rock areas. Armored cable is generally fixed laying power cable, popular is fixed in a place and basically does not move, power line transmission power.
3. In addition to the above, the purpose of the cable plus the armor layer can also enhance the tensile strength, compressive strength and other mechanical protection to extend the service life. The armor has certain resistance to external force, and can also guard against mouse bite, so as not to cause power transmission problems through the armor. The bending radius of the armor should be large, and the armor layer can be grounded to protect the cable.
4. commonly used specifications and uses;
ZAN-YJV22,ZBN-YJV22, XLPE insulated steel tape armored PVC sheathed Class A(B) flame-retardant and fire-resistant power cables are suitable for buried laying when fire resistance is required, but not suitable for laying in pipelines.
ZAN-VV22,ZBN-VV22, PVC insulated steel tape armored PVC sheathed Class A(B) flame-retardant and fire-resistant power cables are suitable for buried laying when fire resistance is required, but not suitable for laying in pipelines.